How many counters are available on the PCC-DAS16/16AO (PC-CARD-DAS16/16AO)?
E How many counters are available on the PCC-DAS16/16AO (PC-CARD-DAS16/16AO)? The PC-CARD-DAS16/16AO does have 3 counters. However, two of these are used to divide down the frequency to the A/D pacer from the onboard clock. Therefore, only one counter (Counter 0) is available to the user for other u....
Is there a Universal Library function to change the channel setup (single ended or differential) ?
2 Is there a Universal Library function to change the channel setup (single ended or differential) ? For some boards, including the USB-1208FS, there is a method of setting the device into single ended or differential configuration using UL code functions. The solution is to use the cbSetConfig func....
Where can I find hardware register maps for Measurement Computing boards?
2 Where can I find hardware register maps for Measurement Computing boards? Some boards contain hardware register maps in a section of the manual. This is particularly true of the older ISA boards. Board manuals can be downloaded at the link below. http://www.measurementcomputing.com/manuals.html Ha....
What are the system requirements for Instacal?
6 Instacal OS requirements and download links. The current version of Instacal is currently compatible with Windows 2000 SP4, Windows XP SP2 (32 bit) and Windows Vista (32 bit.) It can be downloaded at the link below: http://www.measurementcomputing.com/download.htm At the time of writing, a versio....
Measurement Computing PCMCIA bus
E PCMCIA bus on MCC's PCMCIA cards is 16 bits All MCC PCMCIA cards: - Are of the same physical size and bus structure. - Have a 16 bit bus and are Type II cards (i.e. up to 5.5 mm thick) so that they fit into Type II and Type III PCMCIA slot. - Require 5V power from the bus (sometimes the bus on ne....
DASYLab Error: "Device AI: A module cannot be loaded "
6 "A module cannot be loaded" error appears when trying to open a saved worksheet in DASYLab. The problem results from the fact that although Measurement Computing DASYLab drivers are installed on the computer the actual hardware is not connected to it or configured in Instacal. To resolve this issu....
DASYLab Error: "Device AI: A module cannot be loaded "
E "A module cannot be loaded" error appears when trying to open a saved worksheet in DASYLab. The problem results from the fact that although Measurement Computing DASYLab drivers are installed on the computer the actual hardware is not connected to it or configured in Instacal. To resolve this issu....
Error code 41: "This function cannot be used with this board."
Error code 41: "This function cannot be used with this board." This indicates that the a function is being called which is not supported by the type of board specified. This error often occurs when the board number defined does not correspond to the board that you wish to use. For example, when Ins....
PWM with Measurement Computing Counter cards and Universal Library
PWM with Measurement Computing Counter cards and Universal Library We have implemented a PWM control using Universal Library controlling the 8254 counter chip on a PCI-DAS1200. You should be able to do the same using Softwire or Universal Library and any MCC board with a 8254 counter with three us....
Accessing the +/- 5V range of the PMD-1608FS from DASYLab 8.0.
Accessing the +/- 5V range of the PMD-1608FS from DASYLab 8.0. Problem Using the PMD-1608FS and DASYLab 8.0, the drop down list box does not show the +/- 5V range. Solution A driver update is required. Instructions 1) Close DASYLab 8.0. 2) Download the attached MCBN.DLL and save it to the DASYLab i....
|